Important Considerations

Note the following important considerations.

Feature

Comment

everRunSystem Disk

Recommended minimum configuration for physical machines:

  • One logical volume protected by RAID1, RAID 5, RAID 6, or RAID 10

    or

  • Two non-RAID or RAID 0 volumes.

When using multiple volumes per RAID set, the RAID set should set a type that provides redundancy, such as RAID1, RAID5, or RAID10.

QCOW3 (QCOW2v3)

QCOW2 refers to both QCOW2 and QCOW3 files in descriptions of everRun systems. By default, an everRun system creates QCOW3 files (‑f qcow2 -o compat=1.1).

USB CD/DVD Drive

USB CD/DVD drives are supported on all platforms for everRun installation.

Direct-Attach Tape Drives

Access to direct-attach tape drives by the guests is not supported. Stratus recommends using network-attach tape drives.

Console Connectivity

Each PM's text console is available for a CentOS operating system. However, VGA mode is not supported; that is, the PM must be at run-level 3 and cannot run at run-level 5. See "System Management" below.

SSD Support

everRun supports solid state drives according to the storage controller vendor specifications.

System Management everRun system management does not work at run-level 5.
Volumes For exporting, importing, or restoring a volume, the maximum volume size is 2TB.