You are here: everRun Enterprise User's Guide > Getting Started > Software Installation > Configuring the BIOS

Configuring the BIOS

Before you perform the software installation, you must modify certain BIOS settings. You can also modify some optional (but recommended) BIOS settings.

After you modify the BIOS settings, save them and perform the next step in the installation procedure (either Installing Software on the First PM or Installing Software on the Second PM

Note: This topic provides general information about BIOS settings. Because BIOS settings--including the setting names--vary, refer to the manufacturer's documentation for specific instructions for modifying the BIOS settings.

Required Settings

The following BIOS settings are required.

First Boot Device

Controls which device boots the operating system. Set the first boot device to the Optical Drive.

Virtualization Technology Allows the processor to use virtualization technology. Set this to Enabled.
Execute-Disable Bit Capability Allows the processor to classify areas in memory where application code can or cannot execute. Set this to Enabled to help prevent malicious code attacks.

Recommended Settings

The following BIOS settings are optional but recommended.

AC Power Recovery

Determines whether the server automatically powers on and boots after a power cycle. The recommended setting is ON.

F1/F2 Prompt on Error (Dell systems only)

Terminates booting if an error is detected during the process. Set this to Disable, as the everRun system may be able to provide more information once the server is running.

 
of